There is the customer who suspect the mib info on Appliance 2.0.3 is incorrect since almost all the trpas are the object_type and the customer think those traps should be the notification_type by comparing with the showmib output in Appliance 2.5.
1,SNMP Showmib output from Appliance 2.0.3: (please refer to the the SNMP showmib from Appliance 2.5 at section 2)
un5220a.Settings> SNMP ShowMIB
-- ApplianceVersionFile= (#) NBAPP_2.0.3.0
-- Symantec Corporation: 1.3.6.1.4.1.393
-- -- 393 - symantecsoftware
-- .3 - products
-- .9 - appplianceMib
-- .1 - systems
-- .2 - software
SYMANTEC-APPLIANCE-MONITORING-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, mib-2 FROM RFC1213-MIB
enterprises, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
symantecsoftware OBJECT IDENTIFIER ::= { enterprises 393 }
products OBJECT IDENTIFIER ::= { symantecsoftware 3 }
applianceMonitoringMib MODULE-IDENTITY
LAST-UPDATED "12272010"
ORGANIZATION "Symantec Corportion"
CONTACT-INFO "350 Ellis Street
Mountain View, CA 94043 US
Subject: appliance.mib"
DESCRIPTION "The MIB module for Symantec Appliance Monitoring MIB"
::= { products 9 }
systems OBJECT IDENTIFIER ::= { applianceMonitoringMib 1 }
software OBJECT IDENTIFIER ::= { applianceMonitoringMib 2 }
-- systems Traps
systemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "System Name"
::= { systems 1 }
systemLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "System Location"
::= { systems 2 }
fanTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps fan failures"
::= { systems 3 }
powerTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps power failures"
::= { systems 4 }
fibrechannelTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps FibreChannel failures"
::= { systems 5 }
temperatureTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps temperature failures"
::= { systems 6 }
cpuTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps cpu failures"
::= { systems 7 }
diskTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps disk failures"
::= { systems 8 }
raidgroupTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps raid failures"
::= { systems 9 }
enclosurefanTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps enclosure fan failures"
::= { systems 10 }
enclosurepowerTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps enclosure power failures"
::= { systems 11 }
enclosuretemperatureTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps enclosure temperature failures"
::= { systems 12 }
enclsurediskTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps enclosure disk failures"
::= { systems 13 }
adapterTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps adapter failures"
::= { systems 14 }
firmwareTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps firmware failures"
::= { systems 15 }
pciTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps pci failures"
::= { systems 16 }
networkcardTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Traps network card failures"
::= { systems 17 }
-- software traps
failedJobsTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Job failures Trap"
::= { software 1 }
processTrap OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "Processes stopped traps"
::= { software 2 }
END
-------------------------------------------------------------------------------------------------------------------------------------------------------
2,But the SNMP showmib from Appliance 2.5 is below:
-- ApplianceVersionFile= (#) NBAPP_2.5.2
SYMANTEC-APPLIANCE-MONITORING-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, mib-2 FROM RFC1213-MIB
enterprises, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
symantecsoftware OBJECT IDENTIFIER ::= { enterprises 393 }
products OBJECT IDENTIFIER ::= { symantecsoftware 3 }
applianceMonitoringMib MODULE-IDENTITY
LAST-UPDATED "10232012"
ORGANIZATION "Symantec Corportion"
CONTACT-INFO "350 Ellis Street
Mountain View, CA 94043 US
Subject: appliance.mib"
DESCRIPTION "The MIB module for Symantec Appliance Monitoring MIB"
::= { products 9 }
systems OBJECT IDENTIFIER ::= { applianceMonitoringMib 1 }
software OBJECT IDENTIFIER ::= { applianceMonitoringMib 2 }
-- system traps
symcsystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "System Name"
::= { systems 1 }
symcsystemLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS optional
DESCRIPTION "System Location"
::= { systems 2 }
symcfanTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps fan failures"
::= { systems 3 }
symcpowerTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps power failures"
::= { systems 4 }
symcfibrechannelTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps FibreChannel failures"
::= { systems 5 }
symctemperatureTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps temperature failures"
::= { systems 6 }
symccpuTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps cpu failures"
::= { systems 7 }
symcdiskTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps disk failures"
::= { systems 8 }
symcraidgroupTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps raid failures"
::= { systems 9 }
symcenclosurefanTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps enclosure fan failures"
::= { systems 10 }
symcenclosurepowerTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps enclosure power failures"
::= { systems 11 }
symcenclosuretemperatureTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps enclosure temperature failures"
::= { systems 12 }
symcenclosurediskTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps enclosure disk failures"
::= { systems 13 }
symcadapterTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps adapter failures"
::= { systems 14 }
symcfirmwareTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps firmware failures"
::= { systems 15 }
symcpciTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps pci failures"
::= { systems 16 }
symcnetworkcardTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps network card failures"
::= { systems 17 }
symcvolumeTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps volume failures"
::= { systems 18 }
symcbbuTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps BBU failures"
::= { systems 19 }
symcconnectionTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Traps connection failures"
::= { systems 20 }
-- software traps
symcfailedJobsTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Job failures Trap"
::= { software 1 }
symcprocessTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Processes stopped traps"
::= { software 2 }
symcdiskSpaceTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Low disk space traps"
::= { software 3 }
symcsoftwareUpdateSuccessTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Software update success trap"
::= { software 4 }
symcsoftwareUpdateFailedRollbackSuccessTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Software update failed but rollback was successful trap"
::= { software 5 }
symcsoftwareUpdateFailedRollbackFailedTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Software update and rollback failed trap"
::= { software 6 }
symcrollbackSuccessTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Software rollback success trap"
::= { software 7 }
symcrollbackFailedTrap NOTIFICATION-TYPE
OBJECTS { symcsystemName, symcsystemLocation }
STATUS current
DESCRIPTION "Software rollback failed trap"
::= { software 8 }